Demo Questions

Question 1

Which two options describe functions of the data center aggregation layer? (Choose two.)

  • A: services layer
  • B: high-speed packet switching
  • C: repeater
  • D: access control
  • E: QoS marking

Correct Answer: AD




Question 2

Which two options are valid VTP commands? (Choose two.)

  • A: vtp version
  • B: vtp VLAN
  • C: vtp client mode
  • D: vtp static
  • E: feature vtp

Correct Answer: AE




Question 3

What is the minimum number of fabric modules that should be installed in the Cisco Nexus 7000 chassis for N 1 redundancy using M1-Series line card?

  • A: 3
  • B: 4
  • C: 5
  • D: 6

Correct Answer: A




Question 4

View the exhibit. 

  

Refer to the exhibit. What type of network communication is depicted?

  • A: 802.3 frame
  • B: TCP packet
  • C: UDP packet
  • D: Ethernet frame

Correct Answer: D




Question 5

Instructions:
THIS TASK DOES NOT REQUIRE DEVICE CONFIGURATION. 
To access the multiple- choice questions, click on the numbered boxes on the left of the top panel. 
There are four multiple- choice questions with this task. Be sure to answer all four questions before selecting the Next button. 
Scenario:
Customer is configuring FCoE and NPV in their Data Center on Cisco Nexus 5000 Series Switches. Please go through the Topology and Exhibit 1 through 4 to answer the questions. 
Topology:

  

Exhibit 1. 

  

Exhibit 2. 

  

Exhibit 3. 

  

Exhibit 4. 

  

Which statement regarding Cisco Nexus 5000 Series switches is true?

  • A: Cisco Nexus5000 Series switches operate in IP routing mode.
  • B: Cisco Nexus 5000 Series switches operate in FCoE mode.
  • C: Cisco Nexus 5000 Series switches operate in fabric mode.
  • D: Cisco Nexus 5000 Series switches operate in NPV mode.

Correct Answer: C




Question 6

Instructions:
THIS TASK DOES NOT REQUIRE DEVICE CONFIGURATION. 
To access the multiple- choice questions, click on the numbered boxes on the left of the top panel. 
There are four multiple- choice questions with this task. Be sure to answer all four questions before selecting the Next button. 
Scenario:
Customer is configuring FCoE and NPV in their Data Center on Cisco Nexus 5000 Series Switches. Please go through the Topology and Exhibit 1 through 4 to answer the questions. 
Topology:

  

Exhibit 1. 

  

Exhibit 2. 

  

Exhibit 3. 

  

Exhibit 4. 

  

Which statement is true regarding configuring NPV mode?

  • A: When you enable NPV, the system configuration is erased and the switch reboots.
  • B: When you enable NPV, the system configuration is not erased and the switch doesn’t reboot.
  • C: In Exhibit 3 NPV is enabled. but Server Interface to the external switch is not tied to correct vfc 2/1.
  • D: In NPV mode, the core switch relays all traffic from server-side ports to the edge switch and core switch provides N ports.

Correct Answer: C




Question 7

Instructions:
THIS TASK DOES NOT REQUIRE DEVICE CONFIGURATION. 
To access the multiple- choice questions, click on the numbered boxes on the left of the top panel. 
There are four multiple- choice questions with this task. Be sure to answer all four questions before selecting the Next button. 
Scenario:
Customer is configuring FCoE and NPV in their Data Center on Cisco Nexus 5000 Series Switches. Please go through the Topology and Exhibit 1 through 4 to answer the questions. 
Topology:

  

Exhibit 1. 

  

Exhibit 2. 

  

Exhibit 3. 

  

Exhibit 4. 

  

Which two statements are true regarding disruptive load balancing and regarding the configuration in this example? (Choose two.)

  • A: In this scenario disruptive load balancing is disabled.
  • B: In this scenario disruptive load balancing is enabled.
  • C: Since FCID: 0x1c0000 is reserved, disruptive load balancing is not configured correctly.
  • D: When disruptive load balancing is enabled, NPV redistributes the server interfaces across all available NP uplinks when a new NP uplink becomes operational. To move a server interface from one NP uplink to another NP uplink, NPV forces reiinitialization of the server interface so that the server performs a new login to the core switch.

Correct Answer: CD




Question 8

A network design team has decided to use a standard protocol to consolidate the Ethernet and SAN data using the existing Nexus switches. 
Which I/O technology can satisfy this need?

  • A: FCoE
  • B: IEEE 802.1AB
  • C: SCSI
  • D: AToM

Correct Answer: A




Question 9

An administrator connected a new server to a Cisco MDs 9222i on Port FCL/20, but did not capture the world wide name of the host bus adapter. 
Which command returns the needed information?

  • A: show wwn status
  • B: show interface fc 1/20
  • C: show flogi database
  • D: show fcs database

Correct Answer: C




Question 10

Which Cisco UCS power policy mode enables a configuration that can tolerate the loss of an input power circuit?

  • A: nonredundant
  • B: Grid
  • C: N+1 in normal mode
  • D: N+1 in high-density mode

Correct Answer: C