Download Implementing Cisco Data Center Unified Computing.braindumps.300-175.2019-10-30.1e.217q.vcex

Download Exam

File Info

Exam Implementing Cisco Data Center Unified Computing
Number 300-175
File Name Implementing Cisco Data Center Unified Computing.braindumps.300-175.2019-10-30.1e.217q.vcex
Size 7.95 Mb
Posted October 30, 2019
Downloads 9
Download Implementing Cisco Data Center Unified Computing.braindumps.300-175.2019-10-30.1e.217q.vcex

How to open VCEX & EXAM Files?

Files with VCEX & EXAM extensions can be opened by ProfExam Simulator.

Purchase

Coupon: MASTEREXAM
With discount: 20%



 
 



Demo Questions

Question 1

Which description of an import operation in Cisco UCS Manager is true?

  • A: You can perform an import while the system is up and running.
  • B: You can import only a configuration file that was exported from the same Cisco UCS Manager.
  • C: You can import a configuration from a higher release to a lower release.
  • D: You can schedule an import operation.

Correct Answer: A

You can perform an import while the system is up and running. 
You can import any configuration file that was exported from Cisco UCS Manager. The file does not need to have been exported from the same Cisco UCS Manager. You cannot schedule an import operation. 
Reference:
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter43.html#task_B89DEDCFCDE54E9C81E67C53FAC4DEC6
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Admin-Management/3-1/b_Cisco_UCS_Admin_Mgmt_Guide_3_1/b_Cisco_UCS_Admin_Mgmt_Guide_3_1_chapter_01001.pdf
You cannot import configuration from a higher release to a lower release.




Question 2

You are creating service profiles for a Cisco UCS system by using the service profile wizard. You discover that you forgot to create the UUID pool. 
What should you do?

  • A: From the wizard, click Create UUID Suffix Pool.
  • B: Pause the running wizard, and then start a temporary wizard to create a profile with the same name and the missing UUID pool. Resume the wizard, and then select the new UUID pool.
  • C: Continue running the wizard. The service profile uses the burned-in UUID in the BIOS of the server.
  • D: Stop the wizard, and then restart the wizard.

Correct Answer: A

Step 4 
(Optional) If you want to create a new UUID Suffix pool to use in this service profile, click Create UUID Suffix Pool and complete the fields in the Create UUID Suffix Pool wizard. 
For more information, see Creating a UUID Suffix Pool. 
Reference: 
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter24.html




Question 3

Which two features in Cisco UCS Manager are required to configure Uplink Ethernet ports? (Choose two.)

  • A: vNIC templates
  • B: LAN Pin Groups
  • C: VLAN groups
  • D: adapter policies
  • E: link profiles

Correct Answer: AB

Reference:
https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-6120xp-20-port-fabric-interconnect/110267-ucs-uplink-ethernet-connection.html#configUplinkEthernet
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/using_the_lan_uplinks_manager.html




Question 4

You need to design and implement a Cisco UCS 5108 Blade Server Chassis system for a customer. 
Which statement about how half-width blades and full-width blades can be used is true?

  • A: Only two full-width blades can be installed in the top two slots, and four half-width blades can be installed in the bottom two slots.
  • B: Only one full-width blade can be installed in the top slot, and six half-width blades can be installed in the bottom slots.
  • C: Half-width blades and full-width blades can be combined in any order.
  • D: Half-width blade types and full-width blade types cannot be combined.

Correct Answer: C

Mixed blade configurations 
Allows up to 8 half-width or 4 full-width blade servers, or any combination thereof, for outstanding flexibility. When configured with the 6324 Fabric Interconnect, only 8 half-width B200 M3 blades are supported.  
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/chassis-install-guide/ucs5108_install/ucs5108_install_chapter_01.htm




Question 5

You plan to use AAA security services for a Cisco UCS Fabric Interconnect. 
Which two authentication protocols can you use? (Choose two.)

  • A: NTLM
  • B: Kerberos
  • C: RADIUS
  • D: Diameter
  • E: LDAP

Correct Answer: CE

Cisco UCS supports two methods to authenticate user logins:
Through user accounts local to Cisco UCS Manager. Remotely through one of the following protocols:
LDAP 
RADIUS 
TACACS+ 
Reference: https://supportforums.cisco.com/t5/security-documents/ucs-fabric-intreconnect-integration-with-acs-5-4-tacacs/ta-p/3149332




Question 6

You need to identify which DCB standard provides these functionalities: negotiation capabilities for features, the distribution of parameters from one node to another, and logical link up and down signaling for both Ethernet and Fibre Channel interfaces.
Which DCB standard should you identify?

  • A: ETS
  • B: PFC
  • C: DCBX
  • D: QCN

Correct Answer: C




Question 7

You need to configure a new Fibre Channel port channel from the Cisco UCS Manager GUI. To do this, from the SAN tab, you navigate to SAN Cloud > Fabric A or B > FC Port Channels, and you click the plus sign. In the popup window, you specify the Fibre Channel port channel name and ID. 
Which two rules should you follow when you set the Fibre Channel port channel name and ID? (Choose two.)

  • A: The Name field must be a number.
  • B: The ID field can contain ASCII characters, except for spaces.
  • C: The Name field is optional, but it cannot contain spaces.
  • D: The Fibre Channel port channel ID is optional.
  • E: The Fibre Channel port channel ID must be a number.

Correct Answer: CE

The identifier for the port channel. 
Enter an integer between 1 and 256. This ID cannot be changed after the port channel has been saved. Name field 
A user-defined name for the port channel. 
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and . (period), and you cannot change this name after the object has been saved.
The Fibre Channel port channel ID is NOT optional 
The ID field CANNOT contain ASCII characters, OR spaces. 
The Name field must be a number IS NOT CORRECT. 
The Fibre Channel port channel ID must be a number. IS CORRECT The Name field is optional, but it cannot contain spaces. IS CORRECT 
The name field is optional (notice the "Next >" button is available when the name field is empty.




Question 8

Which Cisco UCS blade server supports the highest I/O throughput?

  • A: Cisco UCS B420 M3 Blade Server
  • B: Cisco UCS B200 M3 Blade Server
  • C: Cisco UCS B22 M3 Blade Server
  • D: Cisco UCS B200 M4 Blade Server

Correct Answer: A

B420 M4 = 160G I/O BW 
Reference:
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/data_sheet_c78-706100.html
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/data_sheet_c78-706603.html
https://apps.cisco.com/ccw/cpc/guest/content/ucsModelDetails/model_b200m4
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-b200-m4-blade-server/datasheet-c78-732434.html




Question 9

You are disassociating a service profile from a server. You must associate the service profile to another server.  
Which two policies in the service profile can prevent the service profile from being associated to a different server? (Choose two.)

  • A: LAN connectivity
  • B: SAN connectivity
  • C: server pool policy qualification
  • D: power management
  • E: maintenance

Correct Answer: CD




Question 10

Which two prerequisites are required to configure a SAN boot from the FCoE storage of a Cisco UCS system? (Choose two.)

  • A: The Cisco UCS domain must be able to communicate with the SAN storage device that hosts the operating system image.
  • B: A boot policy must he created that contains a local disk, and the LVM must be configured correctly.
  • C: There must be IVR-enabled FCoE proxying between the Cisco UCS domain and the SAN storage device that hosts the operating system image.
  • D: There must be a boot target LUN on the device where the operating system image is located.
  • E: There must be a boot target RAID on the device where the operating system image is located.

Correct Answer: CD










CONNECT US

Facebook

Twitter

PROFEXAM WITH A 20% DISCOUNT

You can buy ProfExam with a 20% discount!



HOW TO OPEN VCEX AND EXAM FILES

Use ProfExam Simulator to open VCEX and EXAM files