Question 1

Which description of an import operation in Cisco UCS Manager is true?

  • A: You can perform an import while the system is up and running.
  • B: You can import only a configuration file that was exported from the same Cisco UCS Manager.
  • C: You can import a configuration from a higher release to a lower release.
  • D: You can schedule an import operation.

Correct Answer: A

You can perform an import while the system is up and running. 
You can import any configuration file that was exported from Cisco UCS Manager. The file does not need to have been exported from the same Cisco UCS Manager. You cannot schedule an import operation. 
Reference:
https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter43.html#task_B89DEDCFCDE54E9C81E67C53FAC4DEC6
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Admin-Management/3-1/b_Cisco_UCS_Admin_Mgmt_Guide_3_1/b_Cisco_UCS_Admin_Mgmt_Guide_3_1_chapter_01001.pdf
You cannot import configuration from a higher release to a lower release.




Question 2

When a configuration change requires a reboot, which policy specifies how Cisco UCS manager should proceed?

  • A: host firmware policy
  • B: local disk policy
  • C: maintenance policy
  • D: boot policy

Correct Answer: C

Use the Maintenance Policy to specify how Cisco UCS Manager should proceed for configuration changes that will have a service impact or require a server reboot. Values for the Maintenance Policy can be "immediate", "user-ack", or "timer automatic". The best practice is to not use the "default" policy, and instead to create and use Maintenance Policies for either "user- ack" or "timer automatic", and to always have these as elements of the Service Profile or Service Profile Template definition.  
Reference:
http://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-manager/whitepaper_c11-697337.html




Question 3

Which two features in Cisco UCS Manager are required to configure Uplink Ethernet ports? (Choose two.)

  • A: vNIC templates
  • B: LAN Pin Groups
  • C: VLAN groups
  • D: adapter policies
  • E: link profiles

Correct Answer: AB

Reference:
https://www.cisco.com/c/en/us/support/docs/servers-unified-computing/ucs-6120xp-20-port-fabric-interconnect/110267-ucs-uplink-ethernet-connection.html#configUplinkEthernet
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-2/b_UCSM_GUI_Configuration_Guide_2_2/using_the_lan_uplinks_manager.html




Question 4

Which destination(s) are valid for syslog messages for a Cisco UCS Fabric Interconnect?

  • A: the log, the monitor and syslog queue
  • B: a file
  • C: the console and log only
  • D: the console, the monitor, and a file

Correct Answer: D

http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/ucsm_syslog/b_Monitoring_Cisco_UCSM_Using_Syslog/b_Monitoring_Cisco_UCSM_Using_Syslog_chapter_010.html




Question 5

You need to identify which DCB standard provides these functionalities: negotiation capabilities for features, the distribution of parameters from one node to another, and logical link up and down signaling for both Ethernet and Fibre Channel interfaces.
Which DCB standard should you identify?

  • A: ETS
  • B: PFC
  • C: DCBX
  • D: QCN

Correct Answer: C




Question 6

You need to configure a new Fibre Channel port channel from the Cisco UCS Manager GUI. To do this, from the SAN tab, you navigate to SAN Cloud > Fabric A or B > FC Port Channels, and you click the plus sign. In the popup window, you specify the Fibre Channel port channel name and ID. 
Which two rules should you follow when you set the Fibre Channel port channel name and ID? (Choose two.)

  • A: The Name field must be a number.
  • B: The ID field can contain ASCII characters, except for spaces.
  • C: The Name field is optional, but it cannot contain spaces.
  • D: The Fibre Channel port channel ID is optional.
  • E: The Fibre Channel port channel ID must be a number.

Correct Answer: CE

The identifier for the port channel. 
Enter an integer between 1 and 256. This ID cannot be changed after the port channel has been saved. Name field 
A user-defined name for the port channel. 
This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), _ (underscore), : (colon), and . (period), and you cannot change this name after the object has been saved.
The Fibre Channel port channel ID is NOT optional 
The ID field CANNOT contain ASCII characters, OR spaces. 
The Name field must be a number IS NOT CORRECT. 
The Fibre Channel port channel ID must be a number. IS CORRECT The Name field is optional, but it cannot contain spaces. IS CORRECT 
The name field is optional (notice the "Next >" button is available when the name field is empty.




Question 7

You are disassociating a service profile from a server. You must associate the service profile to another server.  
Which two policies in the service profile can prevent the service profile from being associated to a different server? (Choose two.)

  • A: LAN connectivity
  • B: SAN connectivity
  • C: server pool policy qualification
  • D: power management
  • E: maintenance

Correct Answer: CD




Question 8

Which two prerequisites are required to configure a SAN boot from the FCoE storage of a Cisco UCS system? (Choose two.)

  • A: The Cisco UCS domain must be able to communicate with the SAN storage device that hosts the operating system image.
  • B: A boot policy must he created that contains a local disk, and the LVM must be configured correctly.
  • C: There must be IVR-enabled FCoE proxying between the Cisco UCS domain and the SAN storage device that hosts the operating system image.
  • D: There must be a boot target LUN on the device where the operating system image is located.
  • E: There must be a boot target RAID on the device where the operating system image is located.

Correct Answer: CD




Question 9

At a customer site, a Cisco UCS cluster must be renamed due to a domain name change You need to recommend a solution to ensure that Cisco UCS Manager can be accessed over HTTPS. 
Which solution accomplishes this goal?

  • A: The cluster must be reinstalled, in order to generate the default key ring certificate.
  • B: A default key ring certificate regeneration request must be issued from Cisco UCS Manager.
  • C: The default key ring certificate must he renewed automatically when the name changes.
  • D: The default key ring certificate must be regenerated manually.

Correct Answer: D

The cluster must be reinstalled, in order to generate the default key ring certificate. NOT CORRECT A default key ring certificate regeneration request must be issued from Cisco UCS Manager. NOT CORRECT (NOT AN OPTION THROUGH UCSM) 
The default key ring certificate must be renewed automatically when the name changes. NOT CORRECT (NOT AUTOMATIC. MUST BE DONE THROUGH CLI) 
The default key ring certificate must be regenerated manually. CORRECT 
The default key ring certificate must be manually regenerated if the cluster name changes or the certificate expires. 
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/cli/config/guide/2-0/b_UCSM_CLI_Configuration_Guide_2_0/b_UCSM_CLI_Configuration_Guide_2_0_chapter_0110.pdf




Question 10

To boot from SAN, you must perform which two configurations on a Cisco UCS system? (Choose two.)

  • A: Enter the boot LUN and the nWWNs.
  • B: Put the boot VSANin a dedicated boot service profile template.
  • C: Create a LUN, and allow the server WWPN to have access to the LUN.
  • D: Put the server WWPN and the storage array WWPN in the same zone.
  • E: Create a dedicated boot VSAN.

Correct Answer: CD

Reference: