Download Blue Prism.AD01.CertKiller.2019-10-17.44q.vcex

Download Exam

File Info

Exam Blue Prism Developer
Number AD01
File Name Blue Prism.AD01.CertKiller.2019-10-17.44q.vcex
Size 4 MB
Posted Oct 17, 2019
Download Blue Prism.AD01.CertKiller.2019-10-17.44q.vcex

How to open VCEX & EXAM Files?

Files with VCEX & EXAM extensions can be opened by ProfExam Simulator.

Purchase

Coupon: MASTEREXAM
With discount: 20%






Demo Questions

Question 1

Examine the following process flow:
  
The Process is intended to attempt to perform the processing in the recover block, Block 3, a maximum of three times before throwing an exception. 
Data Item “Attempts” is a number data item with an initial value of 0 
Data Item “Max Attempts” is a number data item with an initial value of 3 
The ‘Increment Attempts’ calculation stage adds 1 to the attempts value and outputs a result to the “Attempts” data item 
To enable this to work correctly, what is the correct expressions for the ‘Try Again’ decision stage?


  1. [Attempts] < [Max]
  2. [Attempts] > [Max]
  3. [Attempts] = [Max]
  4. [Attempts] + 1
Correct answer: A



Question 2

The Saved Quantity Data Item is configured as a number with the initial value 0. 
The Loop Orders stage is configured to loop through the Orders collection. 
The Get Quantity stage is configured as follows:
  
What will the data item Saved Quantity contain after the execution of the page?


  1. 4
  2. 5
  3. 10
  4. 19
Correct answer: D



Question 3

Study the following process flow:
  
The data item “Loop Counter” is a number data item and has an initial value of 0. 
The data item “Max Loops” is a number data item and has an initial value of 10. 
The two stages are configured as follows:
  
How many times will the Loop Again stage be executed when the page is executed?


  1. 10
  2. 9
  3. 11
  4. The loop will be infinite
Correct answer: B



Question 4

Examine the following process flow:
  
The Loop Orders loop is configured to loop through the Orders collection. 
How many times will the ‘Process Order’ page be executed?


  1. 1
  2. 15
  3. The loop will be infinite
  4. It’s impossible to tell. There is no loop counter.
Correct answer: B



Question 5

Study the following page in a process:
  
Calculation stages will write A, B or C to the Output value data item. 
What will be the outcome after the page has run?


  1. Data Item Output Value contains “A”
  2. Data Item Output Value contains “B”
  3. Data Item Output Value contains “C”
  4. An Internal Exception will be thrown
Correct answer: A



Question 6

Study the following configuration:
  
  
  
  
Which of the following statements is correct?


  1. When the configuration is run in Control Room, it will become stuck in an infinite loop
  2. When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in System Manager
  3. When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in the Control Room
  4. When the configuration is run in Control Room, it will fail with an internal error on the first execution of the ‘Switch?’ stage with the error: Decision did not result in a yes/no answer
Correct answer: B



Question 7

A screen contains four buttons, Find, Save, Close and New. When the buttons are spied, the attributes are identical except for the Window Text attribute. 
The values for the Windows Text attribute are ‘Find’ for the Find button, ‘Save’ for the Save button, ‘Close’ for the Close button and ‘New’ for the New Button. 
The Dynamic Button element has been spied and has the following attributes set:
  
A navigate stage has been configured to press the Close button:
  
What additional configuration is required to ensure the Close button is selected by the Navigate stage?


  1. Set the Mouse Button value to ‘Close’
  2. The Params button must be selected and the parameter configured to override the Window Text attribute value to ‘Close’
  3. It is not possible to select the Close button using the Dynamic Button element because the value is set to ‘Find’ in the Application Modeller
  4. A new element is required with the Window Text value set to ‘Close’ and the Match Type set to equal
Correct answer: B



Question 8

You identify an element in Application Modeller but when you highlight or use that element Blue Prism gives you an error message saying that duplicate elements were found. 
Which of the following statements is true?


  1. It is common for duplicate elements to be found based upon the attributes that are ticked by default using the Blue Prism product. Time needs to be spent experimenting with the attribute ticks until a unique, reliable, and consistent selection of attributes are found.
  2. It will not be possible to interface with the element in a unique way. You will need to use Surface Automation techniques for this element.
  3. A code stage interface will need to be created and used for this application, this will give you more flexibility to interact with the application elements.
  4. You will need to make the attributes you have selected dynamic. This will allow your flow to loop around, incrementing the attribute value until the correct element is found and used.
Correct answer: D



Question 9

A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is running in Control Room exceptions occur because of screen elements not being found. 
What is the most likely cause?


  1. The most likely cause for the errors is that your application has changed.
  2. The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.
  3. The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.
  4. The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process.
Correct answer: B



Question 10

The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:
  
There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus?


  1.   
  2.   
  3.   
  4.   
Correct answer: C









CONNECT US

Facebook

Twitter

PROFEXAM WITH A 20% DISCOUNT

You can buy ProfExam with a 20% discount!



HOW TO OPEN VCEX FILES

Use ProfExam Simulator to open VCEX files