Download Blue Prism.AD01.PrepAway.2018-11-07.30q.vcex

Download Exam

File Info

Exam Blue Prism Developer
Number AD01
File Name Blue Prism.AD01.PrepAway.2018-11-07.30q.vcex
Size 2 MB
Posted Nov 07, 2018
Download Blue Prism.AD01.PrepAway.2018-11-07.30q.vcex


How to open VCEX & EXAM Files?

Files with VCEX & EXAM extensions can be opened by ProfExam Simulator.

Purchase

Coupon: MASTEREXAM
With discount: 20%






Demo Questions

Question 1

Examine the following process flow:
  
The Loop Orders loop is configured to loop through the Orders collection. 
How many times will the ‘Process Order’ page be executed? 


  1. 1
  2. 15
  3. The loop will be infinite
  4. It’s impossible to tell. There is no loop counter.
Correct answer: B



Question 2

Study the following page in a process:
  
Calculation stages will write A, B or C to the Output value data item. 
What will be the outcome after the page has run?


  1. Data Item Output Value contains “A”
  2. Data Item Output Value contains “B”
  3. Data Item Output Value contains “C”
  4. An Internal Exception will be thrown
Correct answer: A



Question 3

Study the following configuration:
  
  
  
  
Which of the following statements is correct?


  1. When the configuration is run in Control Room, it will become stuck in an infinite loop
  2. When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in System Manager
  3. When the configuration is run in Control Room, it will become stuck in an infinite loop until the ‘Switch’ Session Variable is changed to True in the Control Room
  4. When the configuration is run in Control Room, it will fail with an internal error on the first execution of the ‘Switch?’ stage with the error: Decision did not result in a yes/no answer
Correct answer: B



Question 4

Consider the following flow in an object:
  
Which of the following statements are true?


  1. There just needs to be a wait stage after the start stage to correct this action.
  2. There should be a wait stage after every stage in this flow (i.e. after the navigate, read, write stages)
  3. If during testing in object studio this flow works no additional wait stages should be added as they will slow the interface down.
  4. There should be an intelligent wait stage after the start stage and after any stage that cause the application we are interfacing with to change
Correct answer: D



Question 5

You identify an element in Application Modeller but when you highlight or use that element Blue Prism gives you an error message saying that duplicate elements were found. 
Which of the following statements is true?


  1. It is common for duplicate elements to be found based upon the attributes that are ticked by default using the Blue Prism product. Time needs to be spent experimenting with the attribute ticks until a unique, reliable, and consistent selection of attributes are found.
  2. It will not be possible to interface with the element in a unique way. You will need to use Surface Automation techniques for this element.
  3. A code stage interface will need to be created and used for this application, this will give you more flexibility to interact with the application elements.
  4. You will need to make the attributes you have selected dynamic. This will allow your flow to loop around, incrementing the attribute value until the correct element is found and used.
Correct answer: D



Question 6

Which of the following statements about Business Objects is true? 


  1. It is Blue Prism best practice to include business rules within Business Objects
  2. A Business Object is configured in the Studio area of Blue Prism
  3. A Business Object can be exposed to Control Room
  4. Logging of individual stages is not configurable in Business Objects 
Correct answer: B



Question 7

A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is ran in Control Room exceptions occur because of screen elements not being found. 
What is the most likely cause?


  1. The most likely cause for the errors is that your application has changed.
  2. The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.
  3. The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.
  4. The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process.
Correct answer: B



Question 8

The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:
  
There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus? 


  1.   
  2.   
  3.   
  4.   
Correct answer: C



Question 9

When automating a Windows application what type of stage is configured to perform a Global Send Key Events? 


  1. Notes Stage
  2. Read Stage
  3. Write Stage
  4. Navigate Stage
Correct answer: C
Explanation:
Reference: https://www.rpaforum.net/threads/global-send-keys-and-send-key-events.1587/
Reference: https://www.rpaforum.net/threads/global-send-keys-and-send-key-events.1587/



Question 10

When configuring an object’s run model which of the following is true?


  1. Setting the run model to foreground will give the object priority over the target system ahead of any other Business Object.
  2. Setting the run mode to exclusive will ensure only one process runs on that resource at a time.
  3. Setting the run mode to background will enable the object to run at the same time as foreground and background objects on the same resource.
  4. Leaving the run mode blank will allow any number of processes and objects to run at the same time on the same resource.
Correct answer: A









PROFEXAM WITH A 20% DISCOUNT

You can buy ProfExam with a 20% discount!



HOW TO OPEN VCEX FILES

Use ProfExam Simulator to open VCEX files