Download Dell.D-VXR-OE-23.VCEplus.2024-08-23.37q.tqb

Download Exam

File Info

Exam Dell VxRail Operate 2023
Number D-VXR-OE-23
File Name Dell.D-VXR-OE-23.VCEplus.2024-08-23.37q.tqb
Size 1 MB
Posted Aug 23, 2024
Download Dell.D-VXR-OE-23.VCEplus.2024-08-23.37q.tqb


How to open VCEX & EXAM Files?

Files with VCEX & EXAM extensions can be opened by ProfExam Simulator.

Purchase

Coupon: MASTEREXAM
With discount: 20%






Demo Questions

Question 1

A VxRail administrator is adding a node to an existing VxRail Cluster The node has been racked, cabled and powered on However, the node is not discovered in the vSphere Client Which log file should be analyzed to diagnose the issue?


  1. Icm log
  2. marvin.log
  3. loudmouth log
  4. mystic.log
Correct answer: C
Explanation:
When adding a node to an existing VxRail Cluster and the node is not discovered in the vSphere Client, the 'loudmouth' log should be analyzed. The loudmouth log is crucial for node discovery as it records the communication and discovery processes between nodes in the VxRail cluster. Analyzing this log can help diagnose issues related to node visibility and network communication.Dell VxRail Troubleshooting Guide: VxRail Troubleshooting Guide
When adding a node to an existing VxRail Cluster and the node is not discovered in the vSphere Client, the 'loudmouth' log should be analyzed. The loudmouth log is crucial for node discovery as it records the communication and discovery processes between nodes in the VxRail cluster. Analyzing this log can help diagnose issues related to node visibility and network communication.
Dell VxRail Troubleshooting Guide: VxRail Troubleshooting Guide



Question 2

What two failure events cause the vSAN to start rebuilding components immediately on the VxRail system?
(Select 2)


  1. Interlace controller
  2. ESXi host
  3. Capacity device
  4. Storage controller
Correct answer: BC
Explanation:
Two failure events that cause vSAN to start rebuilding components immediately on the VxRail system are:ESXi host failureCapacity device failureWhen an ESXi host fails, vSAN detects the loss of the host and initiates the rebuilding of the affected components to maintain data availability and integrity. Similarly, when a capacity device (such as an SSD or HDD) fails, vSAN starts the rebuild process to ensure that data remains protected and accessible.VMware vSAN Failure Handling: vSAN Failure Handling
Two failure events that cause vSAN to start rebuilding components immediately on the VxRail system are:
ESXi host failure
Capacity device failure
When an ESXi host fails, vSAN detects the loss of the host and initiates the rebuilding of the affected components to maintain data availability and integrity. Similarly, when a capacity device (such as an SSD or HDD) fails, vSAN starts the rebuild process to ensure that data remains protected and accessible.
VMware vSAN Failure Handling: vSAN Failure Handling



Question 3

What is the maximum number of remote vSAN data stores a client cluster can mount using vSAN HCI Mesh?


  1. 3
  2. 4
  3. 5
  4. 6
Correct answer: D
Explanation:
The maximum number of remote vSAN data stores a client cluster can mount using vSAN HCI Mesh is 6. VMware vSAN HCI Mesh allows for the mounting of remote vSAN datastores to provide flexible storage solutions and scalability. This feature enables multiple clusters to share storage resources efficiently. VMware vSAN HCI Mesh DocumentationDell VxRail Technical Guide
The maximum number of remote vSAN data stores a client cluster can mount using vSAN HCI Mesh is 6. VMware vSAN HCI Mesh allows for the mounting of remote vSAN datastores to provide flexible storage solutions and scalability. This feature enables multiple clusters to share storage resources efficiently. 
VMware vSAN HCI Mesh Documentation
Dell VxRail Technical Guide









PROFEXAM WITH A 20% DISCOUNT

You can buy ProfExam with a 20% discount!



HOW TO OPEN VCEX FILES

Use ProfExam Simulator to open VCEX files