Question 1

A technician needs to install the OS on a server remotely using iDRAC. What is the minimum iDRAC license required to perform this task?


  1. Express
  2. Enterprise
  3. Basic
  4. Baseboard Management Controller
Correct answer: B
Explanation:
Reference https://community.spiceworks.com/topic/514389-dell-idrac-licensing
Reference https://community.spiceworks.com/topic/514389-dell-idrac-licensing



Question 2

A technician needs to replace a server component with orange tabs/releases. Which set of paired steps should the technician take to complete this task?


  1. Power off the server
    Apply anti-static procedures
  2. Remove power cables
    Cold swap the component
  3. Cold swap the component
    Apply anti-static procedures
  4. Hot swap the component
    Apply anti-static procedures
Correct answer: D
Explanation:
Reference https://www.sos.state.co.us/pubs/elections/VotingSystems/DVS-DemocracySuite/documentation/Dell_Poweredge_R630_Owner_Manual.pdf (84)
Reference https://www.sos.state.co.us/pubs/elections/VotingSystems/DVS-DemocracySuite/documentation/Dell_Poweredge_R630_Owner_Manual.pdf (84)



Question 3

A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. They also create a global hot spare. A drive fails on the second virtual disk.
What is the result?


  1. Dedicated hot spare for the virtual disk replaces the failed drive.
  2. Global hot spare replaces the failed drive.
  3. Copyback operation occurs between the failed drive and the dedicated hot spare.
  4. Copyback operation occurs between the failed drive and the global hot spare.
Correct answer: B
Explanation:
Refehttps://www.dell.com/support/article/pk/en/pkbsd1/sln305775/dell-poweredge-how-to-assign-a-hard-drive-in-global-hot-spare-?lang=en